ENGINEERING INSIGHT
Industrial Test & Measurement Systems: Sensors, DAQ and Test Automation
An industrial test system does more than collect sensor values.
A complete test system must:
Create the required test condition
↓
Measure the response of the product or specimen
↓
Acquire and process the measurement data
↓
Execute the required test sequence
↓
Record and evaluate the results
The exact configuration depends on what is being tested, which physical or electrical quantities must be measured and how the test result will be used.
What Should an Industrial Test System Measure?
The first step is to determine which parameters actually represent the performance of the product or specimen.
Typical measurement parameters include:
- Torque
- Force / Load
- Pressure
- Flow
- RPM / Speed
- Temperature
- Displacement / Position
- Voltage
- Current
- Power
- Digital I/O
- Communication Data
Not every system requires every measurement.
The measurement architecture should be selected according to the actual test objective.
Sensors and Transducers
Sensors and transducers convert physical phenomena into electrical signals that can be measured by the test system.
Typical examples include:
- Torque Transducer
- Load Cell
- Pressure Transducer
- Flow Meter
- RPM / Speed Sensor
- Temperature Sensor
- Displacement Sensor
- Voltage / Current Measurement Devices
Sensor selection should consider:
- Measurement Range
- Required Accuracy
- Operating Environment
- Response Characteristics
- Mechanical Installation
- Output Signal
A high-performance DAQ system cannot compensate for inappropriate sensor selection.
Signal Conditioning
A sensor output is not always suitable for direct connection to a DAQ device.
Depending on the sensor and signal type, Signal Conditioning may be required.
Typical functions include:
- Amplification
- Filtering
- Isolation
- Excitation
- Linearization
- Bridge Completion
For example, Torque and Load measurements may require excitation and amplification, while temperature measurements may require sensor-specific conditioning or compensation.
Signal Conditioning helps convert the sensor output into a form that the measurement system can acquire accurately and reliably.
Data Acquisition — DAQ
Data Acquisition, commonly called DAQ, converts measurement signals into digital data that test software can monitor, store and analyze.
A typical measurement path is:
Physical Phenomenon
↓
Sensor / Transducer
↓
Signal Conditioning — if required
↓
DAQ / Measurement Hardware
↓
PC / Test Software
The DAQ configuration should match the actual measurement requirements rather than simply maximizing channel count or sampling speed.
Torque Measurement
Torque is a key measurement in many rotating-machine and dynamometer test systems.
Typical applications include:
- Dynamometer Testing
- Motor Testing
- Pump Testing
- Rotating Component Testing
- Torque Calibration / Verification
The Torque Transducer converts mechanical torque into an electrical measurement signal.
The measured value can then be used for monitoring, test evaluation and Data Logging.
Force and Load Measurement
Force or Load measurements are commonly used in:
- Press Systems
- Assembly Tests
- Compression Tests
- Actuator Tests
- Product Load Tests
Load Cells are frequently used to convert mechanical force into measurable electrical signals.
The measurement range and installation method should match the actual load direction and test structure.
Pressure Measurement
Pressure measurement is widely used in hydraulic, pneumatic and leak-related test systems.
Typical applications include:
- Hydraulic Pressure Test
- Pneumatic Test
- Pump Performance Test
- Pressure Control
- Leak Test
- Process Monitoring
The required range, accuracy and response characteristics depend on the test objective.
Flow Measurement
Flow measurement is important when evaluating pumps, valves, hydraulic components and fluid systems.
Depending on the application, a test system may measure:
- Flow Rate
- Pressure
- Temperature
- Torque
- RPM
together to understand product or system performance.
Combining multiple measurement channels can provide a more complete view of the operating condition.
RPM and Speed Measurement
Rotational speed is a basic parameter in many test benches.
RPM may be used together with:
- Torque
- Power
- Pressure
- Flow
- Temperature
to evaluate rotating equipment.
Depending on the system, RPM can also be a controlled test condition that must be maintained during a Test Sequence.
Temperature Measurement
Temperature can affect both product performance and test conditions.
Typical measurement methods may use:
- Thermocouples
- RTDs
- Other Contact Sensors
- Non-contact Temperature Sensors
The appropriate method depends on the temperature range, required response, installation condition and whether the target is stationary or rotating.
Displacement and Position Measurement
Displacement or position measurement may be required in:
- Press Tests
- Actuator Tests
- Mechanical Function Tests
- Assembly Verification
- Motion Systems
Possible devices include linear sensors, encoders and other position transducers.
The required resolution and range should be determined from the actual test objective.
Voltage, Current and Power Measurement
Electrical performance testing may require measurement of:
- DC / AC Voltage
- Current
- Power
- Electrical Output Characteristics
These measurements can be combined with mechanical parameters such as RPM or Torque when evaluating electromechanical products.
This is common when electrical and mechanical behavior must be evaluated together.
Communication and Digital I/O
Modern products often interact with controllers, sensors or other equipment through communication interfaces and Digital I/O.
A test system may therefore need to:
- Send Control Commands
- Read Status Signals
- Verify Digital Inputs / Outputs
- Exchange Communication Data
- Synchronize Measurements with Product Operation
The required communication method depends on the Device Under Test and the customer's existing system architecture.
Multi-Channel Measurement
Industrial test systems often need to measure several physical quantities at the same time.
For example:
RPM
Torque
Pressure
Flow
Temperature
A multi-channel DAQ architecture allows these signals to be acquired and compared within the same test process.
When relationships between multiple signals matter, timing and synchronization should also be considered as part of the measurement-system design.
Test Recipe
A Test Recipe defines the conditions required for a particular product or test.
Typical Recipe information may include:
- Test Speed
- Load Condition
- Pressure Condition
- Test Duration
- Measurement Items
- Judgment Criteria
Different product models can use different Recipes on the same test system when the equipment has been designed for that purpose.
Test Sequence
A Test Sequence defines how the test progresses.
A typical sequence may include:
Product Identification
↓
Initial Condition Check
↓
Test Condition Setup
↓
Measurement
↓
Condition Change
↓
Additional Measurement
↓
Test Completion
The sequence should follow the actual test requirement and product behavior.
Test Monitoring
During a test, engineers and operators need to understand what the system is doing.
A monitoring screen may show:
- Current Test Step
- Measurement Values
- Setpoints
- Equipment Status
- Alarm Status
- Test Progress
A clear Test Interface helps operators run the system consistently and makes abnormal conditions easier to identify.
Data Logging
Measurement data should be recorded when it is required for:
- Test Reports
- Quality Records
- Performance Analysis
- Traceability
- Engineering Review
A Test Log may include:
- Product ID
- Date / Time
- Test Recipe
- Measurement Data
- Test Conditions
- Final Result
The amount of stored data should be determined by the actual test and quality requirements.
Test Report
Test results can be organized into a report for engineering or quality use.
Depending on the project, the report may contain:
- Product Information
- Test Conditions
- Key Measurement Results
- Graphs
- Final Result
The report structure should match how the customer actually uses the test data.
Calibration and Verification
Measurement data is meaningful only when the measurement system is managed appropriately.
Calibration and Verification can be used to confirm that measurement devices and test systems are operating within the required measurement conditions.
The required method and interval depend on:
- Measurement Device
- Required Accuracy
- Quality Requirements
- Customer Procedures
- Calibration Standards
Calibration should therefore be considered as part of the measurement-system lifecycle rather than only during initial equipment installation.
Typical Industrial Test & Measurement Architecture
Industrial Test & Measurement Architecture
- Rotational Speed
- Load / Force
- Pressure
- Position
- Temperature
- Motor / Servo / Hydraulic / Pneumatic
- Torque
- Force
- Pressure
- Flow
- RPM
- Temperature
- Position
- Voltage / Current
- Amplification
- Filtering
- Isolation
- Excitation
- Control / Synchronization — if required
A test system combines equipment that creates the test condition with measurement systems that acquire the product response.
A practical measurement chain can be represented as:
Test Condition
↓
Device Under Test / Specimen
↓
Sensor / Transducer
↓
Signal Conditioning — if required
↓
DAQ / Controller
↓
PC / Test Software
From the Test Software, acquired data can be used for:
- Real-time Monitoring
- Test Sequence Control
- Data Logging
- Test Reports
- Quality / Engineering Analysis
Core Principle
The test system should create the required condition, measure the product response correctly and convert the results into usable engineering data.
What Makes a Good Industrial Test System?
A good test system is not defined simply by the number of sensors or DAQ channels.
The engineering process should begin with:
Test Objective
↓
Required Test Conditions
↓
Measurement Parameters
↓
Sensor / Measurement Method
↓
DAQ & Signal Architecture
↓
Test Sequence
↓
Data & Result Management
The system should be designed around what the customer actually needs to verify.
Related Engineering Applications
Brake Dynamometer Bench Test
A dynamometer system for applying controlled rotational test conditions and measuring parameters such as Speed, Torque and other test data.
Helm Pump Bench Test System
A production test system integrating rotational operation with Torque, Flow and hydraulic measurements.
Dynamometer Torque Calibration & Verification Device
A dedicated device for comparing a Dynamometer Torque measurement with a reference Torque condition.
Commercial Trailer Energy Recovery Assembly & Performance Test System
A production system combining rotational testing with Voltage, Current and Power measurement using a LabVIEW-based test interface.
What Do You Need to Measure in Your Test System?
When a standard tester cannot reproduce the required operating condition or measurement architecture, a custom system can be developed around the actual product, test objective and required data.
From Torque, Pressure, Flow and RPM to electrical measurement, DAQ, Test Sequence and Data Logging, the measurement system should be designed as one complete engineering process.
Custom Test Equipment · Test & Measurement Systems · DAQ · Test Automation